Scope 1, 2 and 3 Emissions: A Practical Guide
How to set boundaries and calculate Scope 1, 2 and 3 emissions under the GHG Protocol, with location- and market-based Scope 2 and a worked inventory example.

"Scope 3" has moved from a footnote in sustainability reports to a standing agenda item in procurement meetings, investor questionnaires and engineering design reviews. Yet many organisations still struggle with the basics: which emissions belong in which scope, how to treat electricity bought on a green tariff, and how to avoid counting the same tonne twice.
The scope framework comes from the Greenhouse Gas Protocol. Its Corporate Standard (revised edition 2004) defines Scopes 1 and 2. The Scope 3 Standard (2011) sets out 15 categories of value-chain emissions, and the Scope 2 Guidance (2015) introduced dual reporting of electricity emissions. This guide walks through boundary setting, each scope in turn, a worked inventory for an illustrative organisation and the data-quality habits that make an inventory useful for decisions.
Step one: draw the organisational boundary
Before assigning emissions to scopes, decide which operations belong to the reporting organisation. The Corporate Standard offers three consolidation approaches:
- Equity share: emissions are reported in proportion to ownership.
- Financial control: 100% of emissions from operations whose financial and operating policies the company directs.
- Operational control: 100% of emissions from operations where the company has authority to introduce and implement operating policies.
Most engineering and facilities teams find operational control the most intuitive, because it matches the assets they actually run. Whichever approach is chosen, apply it consistently across years and state it in the report.
Scope 1: direct emissions
Scope 1 covers emissions from sources the organisation owns or controls. In practice there are four groups:
- Stationary combustion: boilers, combined heat and power units, furnaces, standby generators.
- Mobile combustion: owned or controlled vehicles, forklifts, airside ground equipment.
- Process emissions: chemical reactions in processes such as cement clinker production.
- Fugitive emissions: refrigerant leakage from chillers, heat pumps and cold stores, and leaks from gas systems.
Fugitive refrigerant emissions are often missed because no fuel bill reveals them. They can be large: a few kilograms of a high-GWP refrigerant can equal several tonnes of CO₂. Our article on refrigerants and climate covers the GWP values and the EU phase-out.
Scope 2: purchased energy and the dual-reporting rule
Scope 2 covers emissions from generating electricity, steam, heat and cooling that the organisation buys and consumes. Since the 2015 Scope 2 Guidance, companies are expected to report two figures:
- Location-based: consumption multiplied by the average emission factor of the grid where it occurs. It shows the physical emissions intensity of the system the organisation draws from.
- Market-based: consumption multiplied by factors from contractual instruments, such as supplier-specific tariffs, energy attribute certificates (Guarantees of Origin in Europe) or power purchase agreements. The guidance sets quality criteria for those instruments. Where none apply, a residual mix factor is used.
The two figures answer different questions. The location-based figure rewards cutting consumption. The market-based figure also reflects procurement choices. Reporting both stops a green tariff being presented as if it had reduced demand. The GHG Protocol is revising its standards, including the Scope 2 Guidance, so check the current requirements before setting up a new reporting cycle.
Good Scope 2 data starts with good metering. A sub-metering strategy lets energy be traced to buildings, processes and tenants, which matters for both the inventory and for finding savings.
Scope 3: the value chain
Scope 3 covers all other indirect emissions. For many organisations it is the largest share of the total, sometimes by a wide margin. The Scope 3 Standard divides it into 15 categories:
| # | Upstream categories | # | Downstream categories |
|---|---|---|---|
| 1 | Purchased goods and services | 9 | Downstream transportation and distribution |
| 2 | Capital goods | 10 | Processing of sold products |
| 3 | Fuel- and energy-related activities (not in Scope 1 or 2) | 11 | Use of sold products |
| 4 | Upstream transportation and distribution | 12 | End-of-life treatment of sold products |
| 5 | Waste generated in operations | 13 | Downstream leased assets |
| 6 | Business travel | 14 | Franchises |
| 7 | Employee commuting | 15 | Investments |
| 8 | Upstream leased assets |
The categories are designed to be mutually exclusive within one company's inventory, to prevent double counting. Across companies, overlap is intended: one firm's Scope 1 is its customers' Scope 3.
Three calculation approaches are common, in rising order of accuracy and effort:
- Spend-based: money spent multiplied by environmentally extended input–output factors (kg CO₂e per euro). Quick and complete, but blind to supplier performance.
- Average-data: physical quantities (tonnes of steel, tonne-kilometres of freight) multiplied by average emission factors.
- Supplier-specific: product carbon footprints or allocated emissions from suppliers, ideally based on lifecycle assessment to recognised standards.
A practical inventory usually mixes all three: spend-based screening to find hotspots, then better data for the categories that matter.
Worked example: an illustrative engineering services company
Consider a hypothetical company with one office-and-workshop site and a van fleet. The emission factors below are illustrative round numbers. A real inventory must use current published factors for the right country and year, such as the UK government's annual conversion factors, and supplier-specific data where it qualifies.
| Source | Activity data | Illustrative factor | Emissions (t CO₂e) |
|---|---|---|---|
| Natural gas for heating (Scope 1) | 400,000 kWh | 0.183 kg CO₂e/kWh | 73.2 |
| Diesel vans (Scope 1) | 20,000 litres | 2.6 kg CO₂e/litre | 52.0 |
| R-410A top-up after a leak (Scope 1) | 3 kg | GWP 2,256 (IPCC AR6, 100-year) | 6.8 |
| Scope 1 total | 132.0 | ||
| Electricity, location-based (Scope 2) | 600,000 kWh | 0.20 kg CO₂e/kWh | 120.0 |
| Electricity, market-based (Scope 2) | 600,000 kWh | 0.05 kg CO₂e/kWh (supplier tariff) | 30.0 |
The refrigerant line works out as 3 kg × 2,256 = 6,768 kg, or about 6.8 t CO₂e. That is nearly a tenth of the gas heating emissions, from a single maintenance visit. The GHG Protocol currently recommends 100-year GWP values from the IPCC Sixth Assessment Report (AR6). EU F-gas legislation still uses the older AR4 value of 2,088 for R-410A, so state which basis an inventory uses.
The company would report Scope 1 of 132.0 t, and Scope 2 of 120 t (location-based) and 30 t (market-based). The cheapest 30 t reduction on paper is the tariff, but the location-based figure only falls if consumption falls. The electricity cost calculator and the carbon savings calculator help put both money and carbon figures on efficiency measures.
Suppose a spend-based screen then shows purchased goods (category 1) at around 900 t CO₂e, dominated by steel and electrical components. Total emissions are then several times the Scope 1 and 2 figures, and the largest lever is procurement, not the boiler room.
Data quality and common mistakes
- Mixing gross and net calorific values. Gas bills in many countries are in kWh on a gross basis. Use a factor on the same basis.
- Forgetting category 3. Upstream emissions from extracting, refining and transporting fuels, and grid transmission losses, belong in Scope 3 category 3, not in Scopes 1 or 2.
- Double counting on-site renewables. Electricity generated and consumed on site has no Scope 2 emissions. If its certificates are sold, it cannot also be claimed as zero-carbon.
- Ignoring leased assets. Whether a leased building sits in Scope 1/2 or Scope 3 depends on the consolidation approach and lease type. Decide once and document it.
- Changing factors silently. When factor sets are updated, recalculate the base year or disclose the effect, or apparent trends may be artefacts.
Reporting frameworks that build on the scopes
The scope structure underpins most disclosure frameworks. In the EU, the European Sustainability Reporting Standard on climate change (ESRS E1) under the Corporate Sustainability Reporting Directive asks in-scope companies to disclose gross Scope 1, 2 and 3 emissions. The set of companies covered and the timetable have been revised since adoption, so check the current rules. An energy management system to ISO 50001 does not require a carbon inventory, but its metering and energy review processes supply much of the Scope 1 and 2 data.
A starter checklist
- Choose and document the consolidation approach.
- List every combustion source, vehicle and refrigerant-containing system. Record refrigerant charges and top-ups.
- Collect metered energy data monthly, not just annually.
- Report Scope 2 on both location-based and market-based bases, with the instruments used.
- Screen all 15 Scope 3 categories, explain any excluded, and improve data for the largest.
- Record emission factor sources and versions, and set a base-year recalculation policy.
- Turn the inventory into a reduction plan: demand first, then supply.
An emissions inventory is a measurement system, not an end in itself. Its value lies in showing where the tonnes are, so that engineering effort goes where it will make a difference.
References
- Corporate Standard. Greenhouse Gas Protocol
- Scope 2 Guidance. Greenhouse Gas Protocol
- Corporate Value Chain (Scope 3) Standard. Greenhouse Gas Protocol
- Government conversion factors for company reporting of greenhouse gas emissions. UK Department for Energy Security and Net Zero