Carbon Savings Calculator
Estimate annual CO2e savings from saved electricity and gas, avoided petrol and diesel, car trips moved to e-bikes and solar PV, with sourced, editable factors.
How the calculation works
Each row multiplies an annual quantity by an emission factor in kilograms of CO₂-equivalent per unit, and the rows are added:
CO₂e saved (kg/yr) = Σ quantity × factor; tonnes = kg ÷ 1000
Moving car journeys to an e-bike is a net factor, because the e-bike still uses some electricity:
Net factor (kg/km) = car L/100 km ÷ 100 × fuel CO₂ per litre − e-bike Wh/km ÷ 1000 × grid factor
The only equivalence shown is the US EPA's typical passenger vehicle, because it is published with its method:
Vehicle-years = tonnes CO₂e ÷ 4.29
Default factors and sources
- Grid electricity, also used for solar PV: EU-27 average 2024, 0.213 kg CO₂/kWh (Ember, European Electricity Review 2025); UK 0.207 (DESNZ 2024 greenhouse gas conversion factors); USA 0.373 (US EPA, eGRID2022, 823.1 lb/MWh); world 0.471 (Ember, 2024).
- Natural gas: 0.183 kg CO₂e/kWh, gross calorific value (UK DESNZ), or 0.181 from the US EPA's 5.3 kg CO₂ per therm.
- Petrol 2.35 and diesel 2.69 kg CO₂ per litre, converted from the US EPA's 8,887 and 10,180 g per US gallon (tailpipe CO₂ only).
- Car-to-e-bike presets: a 6.5 L/100 km petrol car against a 12 Wh/km e-bike on the EU grid gives 0.15275 − 0.00256 = 0.1502 kg per km. A diesel car at 5.5 L/100 km gives 0.1454.
- Vehicle equivalence: 4.29 t CO₂e a year for a typical US petrol passenger car (10,917 miles a year at 22.8 mpg), from the US EPA Greenhouse Gas Equivalencies Calculator.
Worked example (the default rows)
Saving 50,000 kWh of electricity on the EU grid avoids 50,000 × 0.213 = 10,650 kg. Saving 20,000 kWh of gas avoids 20,000 × 0.183 = 3,660 kg. Moving 2,000 km of petrol car trips to an e-bike avoids 2,000 × 0.1502 = 300.4 kg. The total is 14,610.4 kg, or 14.61 t CO₂e a year, about the same as 14.61 ÷ 4.29 = 3.41 typical US cars driven for a year.
Limitations
Average grid factors understate or overstate savings depending on which power stations respond to a change in demand. They also fall as grids decarbonise, so savings from electricity shrink over time. Solar output displaces grid power only when it is used or exported. Fuel factors are tailpipe only and leave out fuel production. For project-grade claims, measure savings properly (see measurement and verification of energy savings), and consider full lifecycle effects (lifecycle assessment explained). Our article on solar-powered charging infrastructure shows how these factors combine in practice.